SmartReader Plus 9 - Two-Channel Pulse Logger
Call ACR Now Call ACR: 1-800-663-7845
North America: 1-800-663-7845
International: +1-604-591-1128
Mon–Fri 8:30 AM – 4:30 PM PT
Two-channel pulse/counter data logger for counting switch-contact closures or DC logic pulses. Each channel supports a “slow” (2 ms) or “fast” (10 µs) input and records up to 4,095 counts per sample interval. Accepts dry-contact switches or logic levels (Low 0–0.5 V, High 4.5–24 V), with a maximum signal frequency of 100 kHz. Available in 32 KB or 128 KB memory versions. Powered by a 3.6 V lithium battery; works with TrendReader software for Windows.
$1,262.00 USD

Guaranteed safe checkout

american expressdiners clubdiscovermasterpaypalvisa
Liquid syntax error (snippets/product-description line 42): Expected dotdot but found comparison in "tab_2 != blank and (specs_override != blank or product.metafields.specifications != blank)"
{"id":6149855936683,"title":"SmartReader Plus 9 - Two-Channel Pulse Logger","handle":"smartreader-plus-9","description":"\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cp\u003eSmartReader Plus 9 (SRP-9) is a purpose-built counter\/logger with two input channels for counting either contact-closure events or DC logic pulses. It’s commonly used to totalize or trend events such as flow-meter reed-switch closures, anemometer pulses, tipping-bucket rain gauges, RPM pickups, and watt-hour meter pulses. Each channel can be set to \u003cem\u003eslow\u003c\/em\u003e (2 ms) or \u003cem\u003efast\u003c\/em\u003e (10 µs) operation. Per sample interval, the logger records up to 4,095\u003cstrong\u003e \u003c\/strong\u003ecounts; if more occur, the interval is capped at 4,095.\u003c\/p\u003e\n\u003ch3\u003eInput types \u0026amp; thresholds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry contacts (unpowered “switch” inputs):\u003c\/strong\u003e The logger sources a very small current (~5 µA) at ~3.6 V across the terminals; use sealed gold-plated contacts where possible. Contacts must be dry (no external source across them).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic-level pulses:\u003c\/strong\u003e Low = 0–0.5 V DC; High = 4.5–24 V DC. Minimum pulse width\/spacing: 2 ms (slow) or 10 µs (fast). Maximum signal frequency: 100 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCounting behavior\u003c\/h3\u003e\n\u003cp\u003eCounts are accumulated within each user-selected sample period and then stored to memory. Example: at a 16-second sample rate, the maximum average rate captured without clipping is 4,095 \/ 16 = 256 Hz (practically ~255 Hz). Choose a suitably short sample period for higher-rate signals.\u003c\/p\u003e\n\u003ch3\u003eMemory, rates, and software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMemory options: 32 KB (~21,500 readings) or 128 KB (~87,000 readings).\u003c\/li\u003e\n\u003cli\u003eSampling: from 25 samples\/second up to once every 8 hours (external power required for rates faster than 1 sample\/8 s).\u003c\/li\u003e\n\u003cli\u003eWorks with TrendReader® for Windows; connection via compatible USB\/serial interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-bit stored readings; powered by a 3.6 V lithium battery.\u003c\/li\u003e\n\u003cli\u003eNoryl® enclosure with magnetic backing\/eyelet.\u003c\/li\u003e\n\u003cli\u003eOperating limits: −40 °C to +70 °C; 0–95 % RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003eApprox. size\/weight: 107 × 74 × 22 mm; 110 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to choose SRP-9 vs SRP-8\u003c\/h3\u003e\n\u003cp\u003eChoose SRP-9 when you need counts per interval (e.g., totalizing or pulse-frequency trends). For on\/off state logging (open\/closed), consider our \u003ca href=\"\/products\/srx8-seven-channel-thermistor-temperature-logger\"\u003eSRX8 Eight-Channel Thermistor (i.e. Resistance) Logger\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompatibility notes (important)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch inputs must be \u003cem\u003edry\u003c\/em\u003e (no external voltage across the contacts).\u003c\/li\u003e\n\u003cli\u003eLogic pulses must meet the stated low\/high thresholds and minimum pulse widths.\u003c\/li\u003e\n\u003cli\u003eMaximum recordable counts per interval are capped at 4,095; select an appropriate sample period to avoid clipping.\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-12-18T20:41:59-08:00","created_at":"2020-12-18T20:41:59-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":126200,"price_min":126200,"price_max":126200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37804123914411,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"01-0130","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 9 - Two-Channel Pulse Logger","public_title":null,"options":["Default Title"],"price":126200,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","options":["Title"],"media":[{"alt":null,"id":15547971764395,"position":1,"preview_image":{"aspect_ratio":1.257,"height":300,"width":377,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528"},"aspect_ratio":1.257,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","width":377},{"alt":null,"id":15547973206187,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546","width":400},{"alt":null,"id":15547974221995,"position":3,"preview_image":{"aspect_ratio":1.384,"height":289,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576"},"aspect_ratio":1.384,"height":289,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cp\u003eSmartReader Plus 9 (SRP-9) is a purpose-built counter\/logger with two input channels for counting either contact-closure events or DC logic pulses. It’s commonly used to totalize or trend events such as flow-meter reed-switch closures, anemometer pulses, tipping-bucket rain gauges, RPM pickups, and watt-hour meter pulses. Each channel can be set to \u003cem\u003eslow\u003c\/em\u003e (2 ms) or \u003cem\u003efast\u003c\/em\u003e (10 µs) operation. Per sample interval, the logger records up to 4,095\u003cstrong\u003e \u003c\/strong\u003ecounts; if more occur, the interval is capped at 4,095.\u003c\/p\u003e\n\u003ch3\u003eInput types \u0026amp; thresholds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry contacts (unpowered “switch” inputs):\u003c\/strong\u003e The logger sources a very small current (~5 µA) at ~3.6 V across the terminals; use sealed gold-plated contacts where possible. Contacts must be dry (no external source across them).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic-level pulses:\u003c\/strong\u003e Low = 0–0.5 V DC; High = 4.5–24 V DC. Minimum pulse width\/spacing: 2 ms (slow) or 10 µs (fast). Maximum signal frequency: 100 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCounting behavior\u003c\/h3\u003e\n\u003cp\u003eCounts are accumulated within each user-selected sample period and then stored to memory. Example: at a 16-second sample rate, the maximum average rate captured without clipping is 4,095 \/ 16 = 256 Hz (practically ~255 Hz). Choose a suitably short sample period for higher-rate signals.\u003c\/p\u003e\n\u003ch3\u003eMemory, rates, and software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMemory options: 32 KB (~21,500 readings) or 128 KB (~87,000 readings).\u003c\/li\u003e\n\u003cli\u003eSampling: from 25 samples\/second up to once every 8 hours (external power required for rates faster than 1 sample\/8 s).\u003c\/li\u003e\n\u003cli\u003eWorks with TrendReader® for Windows; connection via compatible USB\/serial interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-bit stored readings; powered by a 3.6 V lithium battery.\u003c\/li\u003e\n\u003cli\u003eNoryl® enclosure with magnetic backing\/eyelet.\u003c\/li\u003e\n\u003cli\u003eOperating limits: −40 °C to +70 °C; 0–95 % RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003eApprox. size\/weight: 107 × 74 × 22 mm; 110 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to choose SRP-9 vs SRP-8\u003c\/h3\u003e\n\u003cp\u003eChoose SRP-9 when you need counts per interval (e.g., totalizing or pulse-frequency trends). For on\/off state logging (open\/closed), consider our \u003ca href=\"\/products\/srx8-seven-channel-thermistor-temperature-logger\"\u003eSRX8 Eight-Channel Thermistor (i.e. Resistance) Logger\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompatibility notes (important)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch inputs must be \u003cem\u003edry\u003c\/em\u003e (no external voltage across the contacts).\u003c\/li\u003e\n\u003cli\u003eLogic pulses must meet the stated low\/high thresholds and minimum pulse widths.\u003c\/li\u003e\n\u003cli\u003eMaximum recordable counts per interval are capped at 4,095; select an appropriate sample period to avoid clipping.\u003c\/li\u003e\n\u003c\/ul\u003e"}
Translation missing: en.general.search.loading
{"id":6149855936683,"title":"SmartReader Plus 9 - Two-Channel Pulse Logger","handle":"smartreader-plus-9","description":"\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cp\u003eSmartReader Plus 9 (SRP-9) is a purpose-built counter\/logger with two input channels for counting either contact-closure events or DC logic pulses. It’s commonly used to totalize or trend events such as flow-meter reed-switch closures, anemometer pulses, tipping-bucket rain gauges, RPM pickups, and watt-hour meter pulses. Each channel can be set to \u003cem\u003eslow\u003c\/em\u003e (2 ms) or \u003cem\u003efast\u003c\/em\u003e (10 µs) operation. Per sample interval, the logger records up to 4,095\u003cstrong\u003e \u003c\/strong\u003ecounts; if more occur, the interval is capped at 4,095.\u003c\/p\u003e\n\u003ch3\u003eInput types \u0026amp; thresholds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry contacts (unpowered “switch” inputs):\u003c\/strong\u003e The logger sources a very small current (~5 µA) at ~3.6 V across the terminals; use sealed gold-plated contacts where possible. Contacts must be dry (no external source across them).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic-level pulses:\u003c\/strong\u003e Low = 0–0.5 V DC; High = 4.5–24 V DC. Minimum pulse width\/spacing: 2 ms (slow) or 10 µs (fast). Maximum signal frequency: 100 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCounting behavior\u003c\/h3\u003e\n\u003cp\u003eCounts are accumulated within each user-selected sample period and then stored to memory. Example: at a 16-second sample rate, the maximum average rate captured without clipping is 4,095 \/ 16 = 256 Hz (practically ~255 Hz). Choose a suitably short sample period for higher-rate signals.\u003c\/p\u003e\n\u003ch3\u003eMemory, rates, and software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMemory options: 32 KB (~21,500 readings) or 128 KB (~87,000 readings).\u003c\/li\u003e\n\u003cli\u003eSampling: from 25 samples\/second up to once every 8 hours (external power required for rates faster than 1 sample\/8 s).\u003c\/li\u003e\n\u003cli\u003eWorks with TrendReader® for Windows; connection via compatible USB\/serial interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-bit stored readings; powered by a 3.6 V lithium battery.\u003c\/li\u003e\n\u003cli\u003eNoryl® enclosure with magnetic backing\/eyelet.\u003c\/li\u003e\n\u003cli\u003eOperating limits: −40 °C to +70 °C; 0–95 % RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003eApprox. size\/weight: 107 × 74 × 22 mm; 110 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to choose SRP-9 vs SRP-8\u003c\/h3\u003e\n\u003cp\u003eChoose SRP-9 when you need counts per interval (e.g., totalizing or pulse-frequency trends). For on\/off state logging (open\/closed), consider our \u003ca href=\"\/products\/srx8-seven-channel-thermistor-temperature-logger\"\u003eSRX8 Eight-Channel Thermistor (i.e. Resistance) Logger\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompatibility notes (important)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch inputs must be \u003cem\u003edry\u003c\/em\u003e (no external voltage across the contacts).\u003c\/li\u003e\n\u003cli\u003eLogic pulses must meet the stated low\/high thresholds and minimum pulse widths.\u003c\/li\u003e\n\u003cli\u003eMaximum recordable counts per interval are capped at 4,095; select an appropriate sample period to avoid clipping.\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-12-18T20:41:59-08:00","created_at":"2020-12-18T20:41:59-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":126200,"price_min":126200,"price_max":126200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37804123914411,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"01-0130","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 9 - Two-Channel Pulse Logger","public_title":null,"options":["Default Title"],"price":126200,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","options":["Title"],"media":[{"alt":null,"id":15547971764395,"position":1,"preview_image":{"aspect_ratio":1.257,"height":300,"width":377,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528"},"aspect_ratio":1.257,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2366_400_300.jpg?v=1610172528","width":377},{"alt":null,"id":15547973206187,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2370_400_300.jpg?v=1610172546","width":400},{"alt":null,"id":15547974221995,"position":3,"preview_image":{"aspect_ratio":1.384,"height":289,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576"},"aspect_ratio":1.384,"height":289,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2373_400_300.jpg?v=1610172576","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eWhat it does\u003c\/h3\u003e\n\u003cp\u003eSmartReader Plus 9 (SRP-9) is a purpose-built counter\/logger with two input channels for counting either contact-closure events or DC logic pulses. It’s commonly used to totalize or trend events such as flow-meter reed-switch closures, anemometer pulses, tipping-bucket rain gauges, RPM pickups, and watt-hour meter pulses. Each channel can be set to \u003cem\u003eslow\u003c\/em\u003e (2 ms) or \u003cem\u003efast\u003c\/em\u003e (10 µs) operation. Per sample interval, the logger records up to 4,095\u003cstrong\u003e \u003c\/strong\u003ecounts; if more occur, the interval is capped at 4,095.\u003c\/p\u003e\n\u003ch3\u003eInput types \u0026amp; thresholds\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry contacts (unpowered “switch” inputs):\u003c\/strong\u003e The logger sources a very small current (~5 µA) at ~3.6 V across the terminals; use sealed gold-plated contacts where possible. Contacts must be dry (no external source across them).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic-level pulses:\u003c\/strong\u003e Low = 0–0.5 V DC; High = 4.5–24 V DC. Minimum pulse width\/spacing: 2 ms (slow) or 10 µs (fast). Maximum signal frequency: 100 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCounting behavior\u003c\/h3\u003e\n\u003cp\u003eCounts are accumulated within each user-selected sample period and then stored to memory. Example: at a 16-second sample rate, the maximum average rate captured without clipping is 4,095 \/ 16 = 256 Hz (practically ~255 Hz). Choose a suitably short sample period for higher-rate signals.\u003c\/p\u003e\n\u003ch3\u003eMemory, rates, and software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMemory options: 32 KB (~21,500 readings) or 128 KB (~87,000 readings).\u003c\/li\u003e\n\u003cli\u003eSampling: from 25 samples\/second up to once every 8 hours (external power required for rates faster than 1 sample\/8 s).\u003c\/li\u003e\n\u003cli\u003eWorks with TrendReader® for Windows; connection via compatible USB\/serial interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-bit stored readings; powered by a 3.6 V lithium battery.\u003c\/li\u003e\n\u003cli\u003eNoryl® enclosure with magnetic backing\/eyelet.\u003c\/li\u003e\n\u003cli\u003eOperating limits: −40 °C to +70 °C; 0–95 % RH (non-condensing).\u003c\/li\u003e\n\u003cli\u003eApprox. size\/weight: 107 × 74 × 22 mm; 110 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen to choose SRP-9 vs SRP-8\u003c\/h3\u003e\n\u003cp\u003eChoose SRP-9 when you need counts per interval (e.g., totalizing or pulse-frequency trends). For on\/off state logging (open\/closed), consider our \u003ca href=\"\/products\/srx8-seven-channel-thermistor-temperature-logger\"\u003eSRX8 Eight-Channel Thermistor (i.e. Resistance) Logger\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCompatibility notes (important)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitch inputs must be \u003cem\u003edry\u003c\/em\u003e (no external voltage across the contacts).\u003c\/li\u003e\n\u003cli\u003eLogic pulses must meet the stated low\/high thresholds and minimum pulse widths.\u003c\/li\u003e\n\u003cli\u003eMaximum recordable counts per interval are capped at 4,095; select an appropriate sample period to avoid clipping.\u003c\/li\u003e\n\u003c\/ul\u003e"}