SmartReader Plus 4 LPD Low Pressure Differential Logger
Call ACR Now Call ACR: 1-800-663-7845
North America: 1-800-663-7845
International: +1-604-591-1128
Mon–Fri 8:30 AM – 4:30 PM PT

SmartReader Plus 4 LPD Low Pressure Differential Logger

The SmartReader Plus 4 LPD is a low-pressure differential data logger designed to measure small pressure differences used in room and building pressurization, HVAC duct static pressure, and airflow analysis over time.

Key Features

  • Low pressure differential measurement - Internal differential pressure sensor designed for measuring small pressure differences encountered in building pressurization and HVAC applications.
  • Multiple pressure range options by model - Available in several low pressure ranges, with each model configured for a specific measurement range to match the intended application.
  • Continuous time-based data logging - Records pressure trends over extended periods to capture system behavior during equipment cycling, occupancy changes, and varying operating conditions.
  • Self-contained, battery-powered operation - Internal lithium battery enables portable deployment without external power, supporting temporary studies and field investigations.
  • TrendReader® software support - Logged data is downloaded and analyzed using TrendReader software for visualization, reporting, and export.

For pricing information, please click the green Request a Quote button

SKU: 01-0310

Guaranteed safe checkout

american expressdiners clubdiscovermasterpaypalvisa

 

Understanding Low Pressure Differential Measurements

Low pressure differential measurements are commonly used to evaluate how air moves through buildings and HVAC systems. These small pressure differences—often measured in inches of water column—help indicate whether spaces are positively or negatively pressurized, how effectively air is distributed through ductwork, and how systems respond under real operating conditions.

Because these effects are often subtle and time-dependent, spot measurements alone may not reveal the full picture.

Logging Pressure Trends Over Time

The SmartReader Plus 4 LPD is designed to record low pressure differential continuously over extended periods. By capturing pressure trends over hours, days, or weeks, the logger helps reveal system behavior during occupied and unoccupied periods, equipment cycling, and changing environmental conditions.

This time-based view allows users to identify patterns, verify system performance, and diagnose issues that would be difficult to detect with handheld instruments.

Built-In Sensors for Contextual Analysis

The SmartReader Plus 4 LPD incorporates an internal low pressure differential sensor along with an internal temperature sensor. Recording temperature alongside pressure provides important context when analyzing data, helping distinguish true system changes from effects related to thermal variation or operating schedules.

This combination is particularly useful in HVAC and building performance applications, where temperature and pressure are closely linked.

Typical Applications

The SmartReader Plus 4 LPD is commonly used in applications such as:

  • Room-to-room and building pressurization studies

  • Verification of positive or negative pressure in critical spaces

  • HVAC commissioning and re-commissioning

  • Testing and balancing (TAB) verification

  • HVAC duct static pressure monitoring

  • Airflow analysis when used with differential pressure-based measurement methods

  • Troubleshooting comfort complaints, drafts, or infiltration issues

Selecting the Appropriate Pressure Range

Multiple low pressure ranges are available, allowing the logger to be matched to the application:

  • Lower pressure ranges are typically used for room-level and building pressurization measurements.

  • Higher pressure ranges, such as ±10 inWC, are commonly used for HVAC duct static pressure monitoring and airflow analysis.

Selecting the appropriate range improves resolution and measurement accuracy while ensuring reliable operation under expected pressure conditions.

Designed for Temporary Studies and Field Use

Compact, self-contained, and battery powered, the SmartReader Plus 4 LPD is well suited for temporary studies, commissioning work, and troubleshooting tasks where reliable pressure trend data is required without permanent installation. Magnetic mounting and simple pressure connections make the logger easy to deploy in the field and remove once a study is complete.

Specifications

Accuracy: Calibrated:
+/- 0.05” for 0.5”, 1.0” and 2.0” ranges
+/- 0.1” for 5.0” and 10.0” ranges
Thermal:
+/- 0.5% FS (over compensated range)
Hysteresis & Repeatability: +/- 0.05% FS (typical)
Long-Term Stability: +/- 0.5% FS
Media: Non-corrosive gases and dry air
Non-linearity: +/- 0.05% FS (best fit straight line)
Pressure Ranges: +/- 125Pa (0.5inWC)
+/- 250Pa (1.0inWC)
+/- 500Pa (2.0inWC)
+/- 1.25kPa (5.0inWC)
+/- 2.5kPa (10inWC)
Resolution: < 2.5Pa (0.01inWC)
Sensor Type: Silicone piezoresistive strain gauge
Warranty: 3 – years

Accessories

Software & Interface Cable are required for full functionality of the product.

1/4" hose - high pressure 1/4" hose - standard pressure Weatherproof Box

Software

ACR software tools are intuitive and flexible, allowing you to easily configure ACR data loggers to collect the data you need. Once downloaded, your data is displayed in presentation-quality graphs and can be converted into popular formats for use with spreadsheet programs, document editors, and other third-party applications.

TrendReader Full License TrendReader Interface Pkg TrendReader on USB Full

Documentation

For a product sheet, please click below for a pdf version.

Product Sheet

A link to the Manual is available by clicking on the button below.

SmartReader Plus Manual

Q&A

What is low differential pressure?

Differential pressure is the difference in pressure between two measurement points. In HVAC and building performance applications, these pressure differences are often very small and are typically expressed in inches of water column (inWC) or Pascals (Pa). Monitoring differential pressure over time can provide valuable insight into building pressurization, airflow, filter condition, and HVAC system performance.

Why is the SmartReader Plus 4 LPD available in different pressure ranges?

Different applications require different measurement ranges. Room-to-room pressurization studies, for example, typically involve much smaller pressure differences than measurements across HVAC filters or cooling coils. Having multiple pressure range options allows you to select a model that provides an appropriate balance between measurement range and accuracy for your application.

How do I select the appropriate pressure range?

As a general rule, select the lowest pressure range that will accommodate your maximum anticipated differential pressure while meeting your accuracy requirements. It is important to consider both normal and abnormal operating conditions. For example, a clean filter or coil may initially have a relatively low pressure drop, but this can increase substantially as the filter or coil becomes fouled.

The following list provides general guidelines for model selection.

  • ±0.5 inWC (±125 Pa) — Room-to-room and building pressurization. Calibrated accuracy: ±0.05 inWC (±12.5 Pa).
  • ±1.0 inWC (±249 Pa) — Building pressurization and low-pressure HVAC systems. Calibrated accuracy: ±0.05 inWC (±12.5 Pa).
  • ±2.0 inWC (±498 Pa) — Low-pressure filter and coil measurements. Calibrated accuracy: ±0.05 inWC (±12.5 Pa).
  • ±5.0 inWC (±1,245 Pa) — Filter and coil pressure drops, duct static pressure. Calibrated accuracy: ±0.1 inWC (±24.9 Pa).
  • ±10.0 inWC (±2,490 Pa) — Higher-pressure HVAC systems, heavily loaded filters and fouled coils. Calibrated accuracy: ±0.1 inWC (±24.9 Pa).

These are general guidelines. Model selection should be based on anticipated operating pressures and application-specific accuracy requirements.

Can a higher-range logger accurately measure lower differential pressures?

Yes. A higher-range logger can measure pressures throughout its specified range. However, its measurement accuracy should be considered relative to the pressures being measured. For example, an HVAC coil may normally have a pressure drop of approximately 1 inWC but reach 7 inWC when heavily fouled. The ±10 inWC model, with a calibrated accuracy of ±0.1 inWC, can accommodate both conditions. Although the ±2 inWC model offers better calibrated accuracy (±0.05 inWC), its measurement range would be insufficient to capture the higher pressure drops.

Can the logger be used to monitor pressure drop across air filters?

Yes. By connecting the logger's pressure ports to the upstream and downstream sides of an air filter, differential pressure can be recorded over time to assess changes in airflow resistance. When selecting a logger, consider both the initial pressure drop of a clean filter and the maximum anticipated pressure drop before replacement.

Why monitor pressure drop across air filters?

As an air filter becomes loaded with dust and other contaminants, its resistance to airflow increases. Logging differential pressure over time can help determine when filter replacement is warranted, avoid premature replacement, identify excessive airflow restrictions and maintain HVAC system performance. Because pressure drop is influenced by both filter condition and airflow, measurements should ideally be compared under similar airflow conditions. In variable air volume (VAV) systems, simultaneous monitoring of airflow and differential pressure can provide a more reliable indication of filter loading.

Can the logger be used to monitor pressure drop across heating and cooling coils?

Yes. Similar to air filters, heating and cooling coils can develop increased airflow resistance due to dirt accumulation, fouling, icing or other restrictions. Logging differential pressure across the air side of a coil can help identify developing restrictions, assess cleaning requirements and evaluate HVAC system performance. As with air filters, pressure drop measurements should ideally be compared under similar airflow conditions. When selecting a logger, consider both the normal operating pressure drop and the maximum anticipated pressure drop under fouled or restricted conditions.

Can the logger be used to monitor duct static pressure?

Yes. Duct static pressure can be measured by connecting one pressure port to a suitable static pressure probe in the duct and referencing the other port to the surrounding atmospheric pressure.

Logging duct static pressure over time can help verify pressure setpoints, identify control instability, diagnose fan performance issues and identify potential energy-saving opportunities. This is particularly useful in variable air volume (VAV) systems, where fan speed is adjusted to maintain duct static pressure as airflow demand changes throughout the building.

When selecting a logger, consider both the normal operating static pressure and the maximum anticipated pressure under varying system operating conditions.

Can the logger measure both positive and negative pressures?

Yes. All five SmartReader Plus 4 LPD models feature bidirectional pressure measurement ranges. This allows the logger to capture positive and negative pressure differences, including conditions where the pressure relationship between two measurement points reverses over time.

How do I connect the logger to measure differential pressure?

The logger features two pressure ports that are connected using tubing to the measurement points of interest. For pressure-drop measurements across a filter or coil, the high-pressure port is typically connected upstream and the low-pressure port downstream. Appropriate static pressure probes should be used where necessary to prevent air velocity from influencing static pressure measurements.

Can the logger be used to measure airflow?

Yes, indirectly. When used in conjunction with a Pitot tube, airflow measuring station or other differential pressure-based flow measurement device, the recorded pressure data can be used to calculate air velocity or volumetric airflow. The appropriate conversion relationship and any necessary air density corrections must be applied to the recorded pressure data.

What is the difference between measurement accuracy and resolution?

Accuracy describes how closely a measured value agrees with the actual pressure, whereas resolution describes the smallest pressure increment that the instrument can distinguish. All SmartReader Plus 4 LPD models have a specified resolution better than 0.01 inWC. Calibrated accuracy, however, varies by model and should be considered when selecting a pressure range.

What does inWC mean, and how does it relate to Pascals?

InWC stands for inches of water column, a common unit of pressure measurement in HVAC and building performance applications. Pascals (Pa) are the corresponding metric unit. One inch of water column is approximately equivalent to 249 Pascals.

Can the logger be used to measure liquid pressure?

No. The SmartReader Plus 4 LPD is designed for use with dry air and non-corrosive gases. Liquids and condensation must be prevented from entering the pressure ports.

Does the logger require an external power supply?

No, and that's the real beauty of this product. The SmartReader Plus 4 LPD is a self-contained, long-life battery-powered data logger. This makes it particularly suitable for temporary monitoring, HVAC commissioning, troubleshooting and extended field studies without the need for an external power connection.

What software is required to configure the logger and retrieve the data?

ACR's TrendReader software and compatible interface cable are required for logger configuration and data retrieval. Recorded pressure and temperature data can be graphed, analyzed and exported for further analysis or reporting.

Calibration

Data loggers are often used in highly regulated environments such as food and pharmaceutical production and storage where strict safety regulations apply. Regulatory agencies generally require proof of calibration.

ACR calibrations are performed using reference standards that have been calibrated and are traceable to the US National Institute of Standards & Technology (NIST). This ensures that all ACR data loggers meet, and perform to, their published specifications, allowing you to be confident that they will assist you in achieving your compliance requirements.

Calibration certificates are provided with every calibration we perform. ACR Systems is an ISO 9001:2015 registered company and calibration records are kept as part of our quality system and can be made available for customer audits.

Calibration Service

{"id":6149855314091,"title":"SmartReader Plus 4 LPD Low Pressure Differential Logger","handle":"smartreader-plus-4-lpd","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUnderstanding Low Pressure Differential Measurements\u003c\/h3\u003e\n\u003cp\u003eLow pressure differential measurements are commonly used to evaluate how air moves through buildings and HVAC systems. These small pressure differences—often measured in inches of water column—help indicate whether spaces are positively or negatively pressurized, how effectively air is distributed through ductwork, and how systems respond under real operating conditions.\u003c\/p\u003e\n\u003cp\u003eBecause these effects are often subtle and time-dependent, spot measurements alone may not reveal the full picture.\u003c\/p\u003e\n\u003ch3\u003eLogging Pressure Trends Over Time\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is designed to record low pressure differential continuously over extended periods. By capturing pressure trends over hours, days, or weeks, the logger helps reveal system behavior during occupied and unoccupied periods, equipment cycling, and changing environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThis time-based view allows users to identify patterns, verify system performance, and diagnose issues that would be difficult to detect with handheld instruments.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Sensors for Contextual Analysis\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD incorporates an internal low pressure differential sensor along with an internal temperature sensor. Recording temperature alongside pressure provides important context when analyzing data, helping distinguish true system changes from effects related to thermal variation or operating schedules.\u003c\/p\u003e\n\u003cp\u003eThis combination is particularly useful in HVAC and building performance applications, where temperature and pressure are closely linked.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is commonly used in applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoom-to-room and building pressurization studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of positive or negative pressure in critical spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC commissioning and re-commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and balancing (TAB) verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC duct static pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow analysis when used with differential pressure-based measurement methods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting comfort complaints, drafts, or infiltration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelecting the Appropriate Pressure Range\u003c\/h3\u003e\n\u003cp\u003eMultiple low pressure ranges are available, allowing the logger to be matched to the application:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLower pressure ranges are typically used for room-level and building pressurization measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigher pressure ranges, such as ±10 inWC, are commonly used for HVAC duct static pressure monitoring and airflow analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSelecting the appropriate range improves resolution and measurement accuracy while ensuring reliable operation under expected pressure conditions.\u003c\/p\u003e\n\u003ch3\u003eDesigned for Temporary Studies and Field Use\u003c\/h3\u003e\n\u003cp\u003eCompact, self-contained, and battery powered, the SmartReader Plus 4 LPD is well suited for temporary studies, commissioning work, and troubleshooting tasks where reliable pressure trend data is required without permanent installation. Magnetic mounting and simple pressure connections make the logger easy to deploy in the field and remove once a study is complete.\u003c\/p\u003e","published_at":"2020-12-18T20:41:53-08:00","created_at":"2020-12-18T20:41:53-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":92500,"price_min":92500,"price_max":92500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37839112994987,"title":"LPD-0.5\" - 32 KB (01-0310)","option1":"LPD-0.5\" - 32 KB (01-0310)","option2":null,"option3":null,"sku":"01-0310","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-0.5\" - 32 KB (01-0310)","public_title":"LPD-0.5\" - 32 KB (01-0310)","options":["LPD-0.5\" - 32 KB (01-0310)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113027755,"title":"LPD-1\" - 32 KB (01-0311)","option1":"LPD-1\" - 32 KB (01-0311)","option2":null,"option3":null,"sku":"01-0311","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-1\" - 32 KB (01-0311)","public_title":"LPD-1\" - 32 KB (01-0311)","options":["LPD-1\" - 32 KB (01-0311)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113093291,"title":"LPD-2\" - 32 KB (01-0312)","option1":"LPD-2\" - 32 KB (01-0312)","option2":null,"option3":null,"sku":"01-0312","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-2\" - 32 KB (01-0312)","public_title":"LPD-2\" - 32 KB (01-0312)","options":["LPD-2\" - 32 KB (01-0312)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113126059,"title":"LPD-5\" - 32 KB (01-0313)","option1":"LPD-5\" - 32 KB (01-0313)","option2":null,"option3":null,"sku":"01-0313","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-5\" - 32 KB (01-0313)","public_title":"LPD-5\" - 32 KB (01-0313)","options":["LPD-5\" - 32 KB (01-0313)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113060523,"title":"LPD-10\" - 32 KB (01-0314)","option1":"LPD-10\" - 32 KB (01-0314)","option2":null,"option3":null,"sku":"01-0314","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-10\" - 32 KB (01-0314)","public_title":"LPD-10\" - 32 KB (01-0314)","options":["LPD-10\" - 32 KB (01-0314)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","options":["Click the Menu for More Models"],"media":[{"alt":null,"id":15547924054187,"position":1,"preview_image":{"aspect_ratio":1.187,"height":300,"width":356,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601"},"aspect_ratio":1.187,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","width":356},{"alt":null,"id":15547925332139,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645","width":400},{"alt":null,"id":15547926085803,"position":3,"preview_image":{"aspect_ratio":1.313,"height":300,"width":394,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680"},"aspect_ratio":1.313,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680","width":394}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUnderstanding Low Pressure Differential Measurements\u003c\/h3\u003e\n\u003cp\u003eLow pressure differential measurements are commonly used to evaluate how air moves through buildings and HVAC systems. These small pressure differences—often measured in inches of water column—help indicate whether spaces are positively or negatively pressurized, how effectively air is distributed through ductwork, and how systems respond under real operating conditions.\u003c\/p\u003e\n\u003cp\u003eBecause these effects are often subtle and time-dependent, spot measurements alone may not reveal the full picture.\u003c\/p\u003e\n\u003ch3\u003eLogging Pressure Trends Over Time\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is designed to record low pressure differential continuously over extended periods. By capturing pressure trends over hours, days, or weeks, the logger helps reveal system behavior during occupied and unoccupied periods, equipment cycling, and changing environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThis time-based view allows users to identify patterns, verify system performance, and diagnose issues that would be difficult to detect with handheld instruments.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Sensors for Contextual Analysis\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD incorporates an internal low pressure differential sensor along with an internal temperature sensor. Recording temperature alongside pressure provides important context when analyzing data, helping distinguish true system changes from effects related to thermal variation or operating schedules.\u003c\/p\u003e\n\u003cp\u003eThis combination is particularly useful in HVAC and building performance applications, where temperature and pressure are closely linked.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is commonly used in applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoom-to-room and building pressurization studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of positive or negative pressure in critical spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC commissioning and re-commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and balancing (TAB) verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC duct static pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow analysis when used with differential pressure-based measurement methods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting comfort complaints, drafts, or infiltration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelecting the Appropriate Pressure Range\u003c\/h3\u003e\n\u003cp\u003eMultiple low pressure ranges are available, allowing the logger to be matched to the application:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLower pressure ranges are typically used for room-level and building pressurization measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigher pressure ranges, such as ±10 inWC, are commonly used for HVAC duct static pressure monitoring and airflow analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSelecting the appropriate range improves resolution and measurement accuracy while ensuring reliable operation under expected pressure conditions.\u003c\/p\u003e\n\u003ch3\u003eDesigned for Temporary Studies and Field Use\u003c\/h3\u003e\n\u003cp\u003eCompact, self-contained, and battery powered, the SmartReader Plus 4 LPD is well suited for temporary studies, commissioning work, and troubleshooting tasks where reliable pressure trend data is required without permanent installation. Magnetic mounting and simple pressure connections make the logger easy to deploy in the field and remove once a study is complete.\u003c\/p\u003e"}
Translation missing: en.general.search.loading
{"id":6149855314091,"title":"SmartReader Plus 4 LPD Low Pressure Differential Logger","handle":"smartreader-plus-4-lpd","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUnderstanding Low Pressure Differential Measurements\u003c\/h3\u003e\n\u003cp\u003eLow pressure differential measurements are commonly used to evaluate how air moves through buildings and HVAC systems. These small pressure differences—often measured in inches of water column—help indicate whether spaces are positively or negatively pressurized, how effectively air is distributed through ductwork, and how systems respond under real operating conditions.\u003c\/p\u003e\n\u003cp\u003eBecause these effects are often subtle and time-dependent, spot measurements alone may not reveal the full picture.\u003c\/p\u003e\n\u003ch3\u003eLogging Pressure Trends Over Time\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is designed to record low pressure differential continuously over extended periods. By capturing pressure trends over hours, days, or weeks, the logger helps reveal system behavior during occupied and unoccupied periods, equipment cycling, and changing environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThis time-based view allows users to identify patterns, verify system performance, and diagnose issues that would be difficult to detect with handheld instruments.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Sensors for Contextual Analysis\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD incorporates an internal low pressure differential sensor along with an internal temperature sensor. Recording temperature alongside pressure provides important context when analyzing data, helping distinguish true system changes from effects related to thermal variation or operating schedules.\u003c\/p\u003e\n\u003cp\u003eThis combination is particularly useful in HVAC and building performance applications, where temperature and pressure are closely linked.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is commonly used in applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoom-to-room and building pressurization studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of positive or negative pressure in critical spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC commissioning and re-commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and balancing (TAB) verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC duct static pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow analysis when used with differential pressure-based measurement methods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting comfort complaints, drafts, or infiltration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelecting the Appropriate Pressure Range\u003c\/h3\u003e\n\u003cp\u003eMultiple low pressure ranges are available, allowing the logger to be matched to the application:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLower pressure ranges are typically used for room-level and building pressurization measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigher pressure ranges, such as ±10 inWC, are commonly used for HVAC duct static pressure monitoring and airflow analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSelecting the appropriate range improves resolution and measurement accuracy while ensuring reliable operation under expected pressure conditions.\u003c\/p\u003e\n\u003ch3\u003eDesigned for Temporary Studies and Field Use\u003c\/h3\u003e\n\u003cp\u003eCompact, self-contained, and battery powered, the SmartReader Plus 4 LPD is well suited for temporary studies, commissioning work, and troubleshooting tasks where reliable pressure trend data is required without permanent installation. Magnetic mounting and simple pressure connections make the logger easy to deploy in the field and remove once a study is complete.\u003c\/p\u003e","published_at":"2020-12-18T20:41:53-08:00","created_at":"2020-12-18T20:41:53-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":92500,"price_min":92500,"price_max":92500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37839112994987,"title":"LPD-0.5\" - 32 KB (01-0310)","option1":"LPD-0.5\" - 32 KB (01-0310)","option2":null,"option3":null,"sku":"01-0310","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-0.5\" - 32 KB (01-0310)","public_title":"LPD-0.5\" - 32 KB (01-0310)","options":["LPD-0.5\" - 32 KB (01-0310)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113027755,"title":"LPD-1\" - 32 KB (01-0311)","option1":"LPD-1\" - 32 KB (01-0311)","option2":null,"option3":null,"sku":"01-0311","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-1\" - 32 KB (01-0311)","public_title":"LPD-1\" - 32 KB (01-0311)","options":["LPD-1\" - 32 KB (01-0311)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113093291,"title":"LPD-2\" - 32 KB (01-0312)","option1":"LPD-2\" - 32 KB (01-0312)","option2":null,"option3":null,"sku":"01-0312","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-2\" - 32 KB (01-0312)","public_title":"LPD-2\" - 32 KB (01-0312)","options":["LPD-2\" - 32 KB (01-0312)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113126059,"title":"LPD-5\" - 32 KB (01-0313)","option1":"LPD-5\" - 32 KB (01-0313)","option2":null,"option3":null,"sku":"01-0313","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-5\" - 32 KB (01-0313)","public_title":"LPD-5\" - 32 KB (01-0313)","options":["LPD-5\" - 32 KB (01-0313)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}},{"id":37839113060523,"title":"LPD-10\" - 32 KB (01-0314)","option1":"LPD-10\" - 32 KB (01-0314)","option2":null,"option3":null,"sku":"01-0314","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 4 LPD Low Pressure Differential Logger - LPD-10\" - 32 KB (01-0314)","public_title":"LPD-10\" - 32 KB (01-0314)","options":["LPD-10\" - 32 KB (01-0314)"],"price":92500,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","options":["Click the Menu for More Models"],"media":[{"alt":null,"id":15547924054187,"position":1,"preview_image":{"aspect_ratio":1.187,"height":300,"width":356,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601"},"aspect_ratio":1.187,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2702_400_300.jpg?v=1610171601","width":356},{"alt":null,"id":15547925332139,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2706_400_300.jpg?v=1610171645","width":400},{"alt":null,"id":15547926085803,"position":3,"preview_image":{"aspect_ratio":1.313,"height":300,"width":394,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680"},"aspect_ratio":1.313,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2709_400_300_0.jpg?v=1610171680","width":394}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eUnderstanding Low Pressure Differential Measurements\u003c\/h3\u003e\n\u003cp\u003eLow pressure differential measurements are commonly used to evaluate how air moves through buildings and HVAC systems. These small pressure differences—often measured in inches of water column—help indicate whether spaces are positively or negatively pressurized, how effectively air is distributed through ductwork, and how systems respond under real operating conditions.\u003c\/p\u003e\n\u003cp\u003eBecause these effects are often subtle and time-dependent, spot measurements alone may not reveal the full picture.\u003c\/p\u003e\n\u003ch3\u003eLogging Pressure Trends Over Time\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is designed to record low pressure differential continuously over extended periods. By capturing pressure trends over hours, days, or weeks, the logger helps reveal system behavior during occupied and unoccupied periods, equipment cycling, and changing environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThis time-based view allows users to identify patterns, verify system performance, and diagnose issues that would be difficult to detect with handheld instruments.\u003c\/p\u003e\n\u003ch3\u003eBuilt-In Sensors for Contextual Analysis\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD incorporates an internal low pressure differential sensor along with an internal temperature sensor. Recording temperature alongside pressure provides important context when analyzing data, helping distinguish true system changes from effects related to thermal variation or operating schedules.\u003c\/p\u003e\n\u003cp\u003eThis combination is particularly useful in HVAC and building performance applications, where temperature and pressure are closely linked.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe SmartReader Plus 4 LPD is commonly used in applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoom-to-room and building pressurization studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of positive or negative pressure in critical spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC commissioning and re-commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and balancing (TAB) verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC duct static pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow analysis when used with differential pressure-based measurement methods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting comfort complaints, drafts, or infiltration issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelecting the Appropriate Pressure Range\u003c\/h3\u003e\n\u003cp\u003eMultiple low pressure ranges are available, allowing the logger to be matched to the application:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLower pressure ranges are typically used for room-level and building pressurization measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigher pressure ranges, such as ±10 inWC, are commonly used for HVAC duct static pressure monitoring and airflow analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSelecting the appropriate range improves resolution and measurement accuracy while ensuring reliable operation under expected pressure conditions.\u003c\/p\u003e\n\u003ch3\u003eDesigned for Temporary Studies and Field Use\u003c\/h3\u003e\n\u003cp\u003eCompact, self-contained, and battery powered, the SmartReader Plus 4 LPD is well suited for temporary studies, commissioning work, and troubleshooting tasks where reliable pressure trend data is required without permanent installation. Magnetic mounting and simple pressure connections make the logger easy to deploy in the field and remove once a study is complete.\u003c\/p\u003e"}