Product, Order & General Inquiries +1 (800) 663-7845 (8am-4:30pm PST)
![]() Smartbutton
|
![]() TRH1000
|
![]() Nautilus Standard/ High Temperature
|
![]() PowerWatch
|
![]() Owl 100
|
![]() Owl 200
|
![]() Owl 300
|
![]() Owl 400
|
![]() Owl 500
|
|
Description | 1 channel temperature data logger | 2 channel temperature and relative humidity data logger | 1 channel waterproof temperature data logger | Single Phase Voltage Disturbance recorder | 1 channel temperature data logger | 1 channel temperature data logger | 1 channel AC current data logger | 1 channel Process Signal (DC Voltage) data logger | 1 channel Process Signal (4-20mA) data logger |
Inputs | 1 internal | 1 internal temperature 1 internal relative humidity | 1 internal temperature | 1 internal | 1 internal temperature | 1 external temperature | 1 external AC current | 1 external voltage Vdc | 1 external mA |
Measuring Range | -40°C to +85°C | -40°C to +70°C 0-100% (non condensing) | -40°C to +85°C / +10°C to +135°C | -40°C to +70°C | -60°C to +255°C | 0 – 500 Amps | 0-38,4Vdc | 0-24mA DC | |
Memory Size | 2 KB | 64 KB | 32 KB | 32kB | 32 KB | 32 KB | 32 KB | 32 KB | 32 KB |
# of Readings | 2048 | 65280 | 244800 | 4000 events | 32767 | 32767 | 32767 | 32767 | 32767 |
Resolution | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit |
Sampling Rate | 1 to 255 min | 8 sec to 34 min | 8 sec to 34 min | 00,4sec to 34 min | 0,2sec to 12 hours | 0,2sec to 12 hours | 0,2sec to 12 hours | 0,2sec to 12 hours | 0,2sec to 12 hours |
Sampling Method | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full | Continious or Stop when full |
Battery Life | 1 year | 5 years | 10 years / 3 years | 10years | 10 years | 10 years | 10 years | 10 years | 10 years |
Software and Communication Cable | TrendReader forSmartButton and interface cable | TrendReader Express | TrendReader Express and interface cable Stainless steel or | TrendReader 2 Interface package | TrendReader 2 optical light link interface cable | TrendReader 2 optical light link interface cable | TrendReader 2 optical light link interface cable | TrendReader 2 optical light link interface cable | TrendReader 2 optical light link interface cable |
Enclosure | Stainless steel | Aluminium | Noryl | Noryl plastic | Noryl plastic | Noryl plastic | Noryl plastic | Noryl plastic | |
Typical Applications | Pharmaceuticals Packaging | Air quality monitoring | Food transportaion / Monitoring of sterilization cycles | Heating and Ventialtion Food Process Transportation | Heating and Ventialtion Food Process Transportation | Current monitoring, Power consumption, On/Off time monitoring | Pressure Level Flow | Pressure Level Flow |
![]() Smartreader Plus 1
|
![]() Smartreader Plus 2
|
![]() Smartreader Plus 3
|
![]() Smartreader Plus 4
|
![]() Smartreader Plus 5
|
![]() Smartreader Plus 6
|
![]() Smartreader Plus 7
|
![]() Smartreader Plus 8
|
![]() Smartreader Plus 9
|
![]() Smartreader Plus 10
|
|
Description |
2 channel temperature data logger |
4 channel temperature |
8 channel |
4 channel pressure, |
3 channel temperature |
8 channel temperature |
8 channel process |
8 channel temperature |
2 channel Pulse |
4 channel temperature |
Inputs |
1 internal temperature |
1 internal temperature |
1 internal temperature |
1 internal temperature |
1 internal temperature |
1 internal temperature |
1 internal temperature |
1 internal temperature |
2 external-generated |
1 internal temperature |
Measuring Range |
-40°C to +70°C |
-40°C to +70°C |
-40°C to +70°C |
2" - 150psi |
-40°C to +70°C |
-40°C to +70°C |
-40°C to +70°C |
-40°C to +70°C |
4095 pulses/sample |
-40°C to +70°C |
Memory Size |
32 KB, |
128 KB |
32 KB |
32 KB |
32 KB |
32 KB |
32 KB |
32 KB |
32 KB |
128 KB |
# of Readings |
32767 |
87000 |
32767 |
32767 |
32767 |
32767 |
32767 |
32767 |
32767 |
87000 |
Resolution |
12bit |
12bit |
12bit |
12bit |
12bit |
12bit |
12bit |
12bit |
12bit |
12bi |
Sampling Rate |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
0.04 sec to 34 min |
Sampling Method |
Continious or Stop when full |
Continious or |
Continious or |
Continious or |
Continious or |
Continious or |
Continious or |
Continious or |
Continious or |
Continious or |
Battery Life |
10years |
10years |
10years |
10years |
10years |
10years |
10years |
10years |
10years |
10years |
Software and Communication Cable |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
TrendReader 2 |
Enclosure |
Noryl |
Noryl |
Noryl |
Noryl |
Noryl |
Noryl |
Nory |
Noryl |
Noryl |
Noryl |
Typical Applications |
Heating Ventilation |
Heating Ventilation |
Power Consumption |
Heating Ventilation |
Heating Ventilation |
Heating Ventilation |
Process Signal |
Heating Ventilation |
Heating Ventilation |